FalconRack

Energy Savings Cooperation · ESCO

Reduce the electric bill. Keep the capacity.

FalconRack™ is a filter-compensating apparatus installed at the site. Zero client capex. Zero maintenance invoice. Guaranteed savings, shared. No redesign of the plant grid.

$0
Client capex
30%+
Savings floor
10%
Your share, years 1–3
50%
Your share after

The hidden bill

Power quality never shows up as one line item.

Harmonic distortion

Current at 150–450+ Hz wastes energy and overheats windings, cables, and transformers.

Reactive power

A large reactive component reduces useful work from every purchased kilowatt-hour.

Voltage events

Dips, overvoltage, frequency deviation, and phase imbalance stress drives and controls.

Network waste

Eddy currents and imbalance can leave only about 70% of transformer rating usable.

Up to 30%

Runtime tax on motors and process equipment.

Up to 15%

Internal network loss in cables and windings.

Decades → months

Insulation life under severe harmonic overload.

Harmonics ride on the 60 Hz fundamental.

They raise RMS current and turn purchased energy into heat. The 7th harmonic of 60 Hz is 420 Hz.

ComponentFrequencyEffect
Fundamental60 HzUseful working current
3rd harmonic180 HzTriplen heating in neutrals and transformers
5th harmonic300 HzCommon on VFDs; torque ripple and extra losses
7th harmonic420 HzMotor overheating and control interference
9th+ harmonics540 Hz+Insulation stress, capacitor failure, resonance

The apparatus

FalconRack™ plus site diagnostics.

  1. 01

    Site diagnostics

    Free measurement of harmonics, reactive power, imbalance, and load. The guarantee is set from the data.

  2. 02

    Active filtering

    Suppresses harmonic currents so motors, cables, and transformers stop dissipating parasitic energy.

  3. 03

    Reactive compensation

    Tracks load reactive power, holds power factor, and returns unused capacity.

  4. 04

    Safe connection

    Connects without redesigning the plant grid. Install and commissioning are in the ESCO package.

European installations

Typical active-energy saving about 40%.

FalconRack-class apparatus at 20+ European enterprises. Invoice impact on completed sites typically 26–49%. Names and cities withheld.

InstallationTypeYearAvg. useSaving
Food drying plantProcess20103,850 kWh41%
Agribusiness groupMulti-site20172,500 kWh40%
Construction materialsPlant2023250 kWh43%
Building-materials plantIndustrial20193,000 kWh40%
Retail chain50 stores2022–20233,000 kWh49%
Supermarket chain11 stores2022715 kWh43%
Light industrialPlant2023145 kWh42%

Before

Odd harmonics dominate. Current does no useful work. Invoices inflate. Transformers run hot. Motors and cables age early.

After

Harmonics collapse toward a clean sinusoid. Lower RMS current. Less winding heat. Capacity freed inside the existing connection.

Use it

What your bill would share.

Standard offer: you keep 10% of verified savings for three years, then 50%. Illustration only — the guarantee is set after diagnostics.

Annual savings

$150,000

You keep, years 1–3

$15,000 / yr

You keep, year 4 on

$75,000 / yr

Your total through year 9

$495,000

Commercial terms

$0

Package cost to the client

$0

Maintenance cost to the client

10%

Client share, years 1–3

50 / 50

Split from year 4

Building-stone example from the briefing: 6.75 million kWh, about $0.083 per kWh, 30–35% expected save, roughly $190,000 a year. Client capex stays at zero. Payback starts with the first measured period.

Next step

Free diagnostics. Then a guaranteed offer.

  1. 1. On-site measurement at no charge.
  2. 2. Offer: savings, capacity, and terms.
  3. 3. ESCO agreement. No client capex.
  4. 4. Manufacture, install, and commission FalconRack™.

Bring last year’s monthly electricity use, the current tariff including capacity payments, and any planned load changes for the next three years.